      FB series - integral flange

      2015-01-20 116

      Product Feature

        FB series liquid level sensor adopts flange design, electronic sensor head flange has realized the integration of parts and installation, compact structure, exposed part after installation height only 34 mm.

            — Strong anti-interference ability

            — High degree of protection(IP68)

            — Easy installation and use

            — High precision

       

      Technical Parameters

        Analog Output SSI Output
      Project Name Standard/Parameter Standard/Parameter
      Measurement Range 50-5000mm 50-5000mm
      Output Signal 4~20mADC; 0~10VDC Modbus RS485
      Resolution 16 bit D/A  0.1mm
      Non-linearity <±0.05%F.S. <±0.05%F.S.
      Hysteresis <±0.002%F.S. <±0.002%F.S.
      The temperature coefficient of 0.007%F.S./℃
      Operating Voltage 24VDC (-15/+20%)
      Working Temp - 40℃~+85℃
      Protective Ability Ordinary type, flameproof, the Ann model
      Way To Install Installed thread, flange (optional)

       

      Overall dimensions

       

      Electrical connections

       

      Analog Output Needle Size Line Color Definition Modbus输出 Needle Size Line Color Definition
      1 grey Output Signal:4-20mA,0-10V 1 grey A(RS485)
      2 pink Signal earth 2 pink B(RS485)
      3 yellow throw out of gear 3 yellow throw out of gear
      4 green throw out of gear 4 green throw out of gear
      5 palm +24VDC(±10%) 5 palm +24VDC(±10%)
      6 white A direct current source 6 white A direct current source

       

      Analog Output Needle Size Line Color Definition Modbus Output Needle Size Line Color Definition
      1 grey Output Signal:4-20mA,0-10V 1 grey A(RS485)
      2 pink Signal earth 2 pink B(RS485)
      3 palm +24VDC(±10%) 3 palm +24VDC(±10%)
      4 white A direct current source 4 white A direct current source